Apollo manufacturer of flowmeters, sight glasses and instrumentation for liquids and fluids in water chemical, pharmaceutical and food processing industries. Turbine flowmeter, electromagnetic flow meters, positive displacement and ultrasonic flowmeters, rate totalisers, batch controllers, which accurate batch preset volume mass of liquid.
Apollo manufacturer of flowmeters, sight glasses and instrumentation for liquids and fluids in water chemical, pharmaceutical and food processing industries. Turbine flowmeter, electromagnetic flow meters, positive displacement and ultrasonic flowmeters, rate totalisers, batch controllers, which accurate batch preset volume mass of liquid.
Spacer image
Flowmeters
 Turbine
 Hygienic
 Electromagnetic
 Hoverflo
 Lowflo/Peltflo
 Variable Area
 Oval Gear
 Positive Displacement
 Mass
 Mechanical Water Meter
 Ultrasonic
 Custom
Instruments
Sight Glasses
Downloads
Reference
Site Map
Contacts
Home
Corner

Apollo Flow Measurement Ltd
Charles Street
Walsall
WS2 9LZ
Contact us now to discuss your turbine flow meter needs
Contact us now to discuss your turbine flow meter needs
Tel 01922 645647
Tel 0800 3286674
Tel +44 1922 645647
Fax 01922 640326
sales@apolloflow.co.uk


Click here for UKAS certificate




Valid HTML 4.01 Transitional
 

HOVERFLO 2 ALL PLASTIC
BEARINGLESS FLOWMETER
    Click here for the Hoverflo flowmeter pdf datasheet

The Hoverflo will accurately measure the flow of highly corrosive, aggressive and non lubricating liquids and chemicals.


RN7 Hygienic Flowmeter
All plastic bearingless design
No maintenance
Well proven
No corrosion
No drift or wear
Accurate measurement of difficult liquids
Individual calibration certificates

 

Application
This range of flowmeters is used for measuring highly corrosive solutions such as nitric, sulphuric, hydrochloric and hydrofluoric acids. It is ideal for measuring agressive and non-conductive liquids which have proven to be incompatible with most magnetic and mechanical flowmeters.
The long term reliability and stability of the Hoverflo make it ideal for both batch and continuous process operation.
In hazardous areas you can use the flowmeters with the Apollo IS pick-off coil, approved ATEX II I G EEx ia IIC T5. The signal can be used in the IS area or transmitted to the safe area using the intrinsically safe P5 preamplifier and suitable barriers.

Principle of Operation
The flowmeter has two turbines connected by a central shaft. The liquid flows through both turbines, spinning the shaft whilst it hovers. The lower turbine has magnets sealed in the rim which are detected by the sensor to generate pulses. The frequency of the pulses is proportional to your flow rate.

Instrumentation
The signal can be used for a local display, remote display or converted for transmission to a separate control system. Apollo have a range of instruments to suit all your requirements.

Construction
All wetted parts are either PVC or PVDF for maximum chemical resistance. The seals are PTFE or viton. The meter combines the advantages of a turbine flowmeter without the problems of bearing wear.

Calibration
All Apollo flowmeters are individually calibrated with water and are traceable to national standards.
We provide you with a test certificate for each meter showing the number of pulses per litre, which is used to set the instrumentation.

Installation
The flowmeter is installed horizontally in the pipeline.
To reduce turbulence and achieve the best results from your flowmeter we recommend that you install it in a straight section of pipe with at least 10 pipe diameters upstream and 5 pipe diameters downstream.
Control valves should be installed downstream of the flowmeter.The flowmeter must be kept full of liquid and reverse flow must be avoided.
An amplifier is required if you need to transmit the signal more than 4 metres, or if there is an electrically noisy environment close to pumps, solenoids, switchgear or high current cables.
Intrinsically safe systems always require an IS pick-off coil. The IS P5 preamplifier is required for transmission to the safe area through barriers.

Hoverflo Flow Ranges

Size mm
Cartridge material Overall flow range
litres/min
Linear flow range
litres/min
Pulses/ litre
15 PVC 3.5 - 35 7-35 160
15 PVDF 4 -35 7.5-35 160
25 PVC 10-110 22-110 83
25 PVDF 12-110 22-110 83
40 PVC 15-250 40-250 29
40 PVDF 18-250 50-250 29
50 PVC 35-440 85-440 17
50 PVDF 85-440 42-440 17
80 PVC 70-1000 220-1000 10.5
80 PVDF 85-1000 240-1000 10.5

 

 Specification

Linearity: +/- 0.5% (+/-1.0% for 15mm) of reading in linear range
+/-1.0% of maximum reading for the overall range
Repeatability: +/-0.125% of reading
Pressure drop: 0.85 bar at maximum flow
Maximum pressure: PVC body 8 bar at 20 oC
PVDF body 16 bar at 20 oC
Temperature range: PVC -10 to 60 oC
PVDF -10 to 110 oC
Body connections: Socket weld or stub flanges with backing rings
Pickoff coil output : Sine wave mV high frequency signal

 

 Materials of Construction

Body: PVC or PVDF
Cartridge carrier: PVC or PVDF
Measuring cartridge and rotor: PVC or PVDF
Upper and lower sealing plates: PVC or PVDF with 316 s/s cover plate
Studs and nuts: Stainless steel
O rings: Viton or PTFE
To view the Hoverflo pdf data sheet click here:Click here for the Hoverflo flowmeter pdf datasheet

To see available data sheets and manuals click here: Download Area