Apollo manufacturer of flowmeters, sight glasses and instrumentation for liquids and fluids in water chemical, pharmaceutical and food processing industries. Turbine flowmeter, electromagnetic flow meters, positive displacement and ultrasonic flowmeters, rate totalisers, batch controllers, which accurate batch preset volume mass of liquid.
Apollo manufacturer of flowmeters, sight glasses and instrumentation for liquids and fluids in water chemical, pharmaceutical and food processing industries. Turbine flowmeter, electromagnetic flow meters, positive displacement and ultrasonic flowmeters, rate totalisers, batch controllers, which accurate batch preset volume mass of liquid.
Spacer image
Flowmeters
 Turbine
 Hygienic
 Electromagnetic
 Hoverflo
 Lowflo/Peltflo
 Variable Area
 Oval Gear
 Positive Displacement
 Mass
 Mechanical Water Meter
 Ultrasonic
 Custom
Instruments
Sight Glasses
Downloads
Reference
Site Map
Contacts
Home
Corner

Apollo Flow Measurement Ltd
Charles Street
Walsall
WS2 9LZ
Contact us now to discuss your turbine flow meter needs
Contact us now to discuss your turbine flow meter needs
Tel 01922 645647
Tel 0800 3286674
Tel +44 1922 645647
Fax 01922 640326
sales@apolloflow.co.uk


Click here for UKAS certificate




Valid HTML 4.01 Transitional
 

MASS FLOWMETER    Click here for the mass flowmeter pdf datasheet

These very accurately measure the mass flowrate, density and temperature of liquids, suspensions, emulsions and gases.

Excellent accuracy and repeatability
Independent of viscosity and temp changes
Displays mass flow,density and temperature
Outputs for your control systems
Preset for your requirements
No obstruction to flow
Intrinsic safety approval
Hygienic approvalMass Flowmeter

 

Application
These are very accurate for dosing and batching of liquids and gases. They cover the range from 0.01kg/min to 3000 kg/min. The results are accurate independent of changes in viscosity, temperature, pressure and density.

Instrumentation
The display converter has an LCD display. It displays the mass flow rate, total, temperature and density. It has pulse and current outputs for a wide range of control systems.

Principle of Operation
Coriolis forces are generated in an oscillating system when a mass moves away from or towards an axis of oscillation. The measuring tube is vibrated at a uniform frequency. With no flow the Coriolis force is zero. During flow the particles in the fluid are accelerated and decelerated to and from the axis of oscillation. This generates Coriolis forces that move the measuring tube by extremely small amounts and are detected by special sensors. The Coriolis force is directly proportional to the mass flowrate.

Construction
The range of materials of the wetted parts make it suitable for almost all applications.
The flowmeters consist of a detector and a display converter. They can be supplied integral with the display mounted directly on the detector or separately connected by cables (100m max.) so the display can be mounted remotely.
There is an option for a heating jacket fitted to allow the line fluid to be heated up to 150 oC. For this option the converter must be mounted separately.

Calibration
Each flowmeter is calibrated against scales. The scales are calibrated to National Standards by the Trading Standards Calibration Service.
The mass flowmeters have measuring errors of less than 0.15% of the measured value.
To ensure accuracy over the measuring range, calibrations are carried out at different flow rates.
Each mass flowmeter is also calibrated for a density range of 0.5 to 2.0 g/cm3.

Installation
The flowmeter is mounted in the line and should be maintained full of liquid prior to and throughout measurement. You are strongly advised to avoid heavily vibrating environments. The tube can be installed in a vertical or horizontal line and has a straight through bore that is self-draining and has a minimal pressure drop. A zero point calibration is done after installation when the line is full of liquid.

Options
There is a range of equipment for use with the S series flowmeters. These include air eliminators, check valves, filters and counters.

Flow Ranges

Model Size Flow range in kg/min:
ANSI DN Min Norm. Max.
10 G 1/2" 10 / 15 0.25 10 20
100 G 3/4" / 1" 15 / 25 2 100 200
300 G 1" / 11/2" 25 / 40 5 300 600
800 G 11/2" / 2" 40 / 50 15 800 1600
1500 G 2" / 3" 50 / 80 25 1500 3000
3000 G 3" / 4" 80 / 100 50 3000 6000

Flowmeter Specification

Linearity: +/- 0.15% of reading
Repeatability: +/- 0.04% of reading
Density range: 0.5 - 2.0 g/cm3
Maximum pressure: 63 bar or connection rating
Flange connections: ANSI 150/300 or DIN 2635 PN 40/63
Hygienic version: Triclamp, IDF, ISS or RJT
Maximum line temp: -25 to 130oC (Option to 150 oC)

Materials of Construction

Wetted parts & tube: Titanium alloy, zirconium option
Secondary housing: 304 stainless steel (3000 G powder coated steel)
Flanges: 304 stainless steel

Converter Specification

Current output: 0-20 mA or 4-20mA
Load: 500 Ohms
Pulse Output: Open collector Max. 24V
Frequency max.: 1300 Hz
Status output: Open collector 24 V max
Function: Status, flow alarm & direction
Control input: Opto isolator
Function: Reset total, zero point, status or changeover mode

Materials of Construction

Material: Aluminium with polyurethane finish
Amb. temp.: -25 to 60
Protection: IP67 or NEMA 6
Power Supply Mains: 230 Vac or 120 V ac
DC: Option for 24 V DC
Setup & Control The setup is preset for your application.
Adjustments: Changes are made using the 3 keys and the LCD display.
Intrinsically Safe Version EEx ib IIC T6 and to FM Class 1 Division 1
To view the Mass Flowmeter pdf data sheet click here:Click here for the mass flowmeter pdf datasheet